A) flagellar stain
B) Gram stain
C) negative stain
D) hanging drop
E) fixed, stained smear
Correct Answer
verified
A) incubated
B) streaked
C) spread
D) poured
Correct Answer
verified
Correct Answer
verified
A) trypticase soy agar
B) reducing medium
C) mannitol salt agar
D) blood agar
E) MacConkey medium
Correct Answer
verified
A) Bright-field
B) Fluorescence
C) Electron
D) Dark-field
E) Phase-contrast
Correct Answer
verified
A) enriched
B) complex
C) reducing
D) synthetic
Correct Answer
verified
A) reducing
B) enriched
C) complex
D) defined
Correct Answer
verified
A) They use heat to force the dye into cell structures.
B) The staining outcome varies with the charge of the cell wall.
C) They are used on a wet mount of the specimen.
D) They are differential stains.
E) They use a negative stain technique.
Correct Answer
verified
Correct Answer
verified
A) Transmission EM is used for internal detail of cells and subcellular structures.
B) Transmission EM gives detail of the external architecture of cells.
C) Transmission EM requires dyes.
D) Transmission EM can provide good images of bacteria but not viruses.
Correct Answer
verified
A) Lister
B) Schultz and Schwann
C) Leeuwenhoek
D) Redi
E) Pasteur
Correct Answer
verified
A) A pure culture
B) A contaminated medium
C) A liquid medium
D) A mixed culture
E) A solid medium
Correct Answer
verified
A) resolution
B) contrast
C) illumination
D) size of the field
E) magnification
Correct Answer
verified
A) Poliovirus, 30 nm
B) Red blood cell, 8 m
C) Escherichia coli, 1 m X 4 m
D) Pandora virus, 0.5 mm X 1 mm
Correct Answer
verified
A) 10,000X
B) 1,000X
C) 100X
D) 0.01X
E) 0.001X
F) 0.0001X
G) This is impossible to calculate without more information.
Correct Answer
verified
A) Agar can convert from liquid to solid form, and back again, very easily.
B) Agar is a complete source of nutrients for most bacteria.
C) Bacteria growing on the solidified medium did not degrade or break down the agar.
D) Agar was less expensive than the nutrients that Koch was previously using in the lab.
Correct Answer
verified
A) The microbiologist used too much inoculum.
B) The culture medium was selective.
C) The culture medium was differential.
D) The culture was contaminated.
E) The incubation temperature was incorrect.
Correct Answer
verified
A) Axenic
B) Mixed
C) Pure
D) Both axenic and mixed are correct.
E) Both axenic and pure are correct.
Correct Answer
verified
A) differential medium
B) enrichment medium
C) selective medium
D) liquid medium
Correct Answer
verified
A) ocular
B) condenser
C) stage
D) nosepiece
Correct Answer
verified
Showing 1 - 20 of 75
Related Exams